Customization: | Available |
---|---|
After-sales Service: | Support |
Warranty: | 10 Year |
Still deciding? Get samples of US$ 1755/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
BDM 300
|
BDM 500
|
BDM 600
|
BDM 800
|
Recommended Max PV Power
|
450W
|
750W
|
450W*2
|
600W*2
|
Max DC Open Circuit Voltage
|
60V
|
|||
Max DC Input Current
|
14A
|
15.5A
|
14A*2
|
17A*2
|
MPPT Tracking Accuracy
|
>99.5%
|
|||
MPPT Tracking Range
|
22-55V
|
35-55V
|
22-55V
|
22-55V
|
Isc PV (absolute maximum)
|
18A
|
14A
|
18A*2
|
20A*2
|
Maximum Inverter Backfeed Current to the Array
|
0A
|
|||
Rated AC Output Power
|
300W
|
500W
|
500W
|
800W
|
Nominal Power Grid Voltage
|
240V/208V/230V
|
|||
Allowable Power Grid Voltage
|
211-264*/ 183-228*/ Configurable
|
|||
THD
|
<3% (at rated power)
|
|||
Nominal Frequency (Hz)
|
50HZ/60HZ
|
|||
Maximum Output Fault Current (Aac)
|
2.2A PEAK
|
4.4A PEAK
|
4.4A PEAK
|
9.6A PEAK
|
Maximum Number of Units Per Branch (20A) (All NEC adjustment factors have been considered)
|
15/13/14
|
7/6/6
|
7/6/7
|
5/5/5
|
Weighted Averaged Efficiency (CEC)
|
95.5%
|
|||
Protection
|
Over/Under Voltage; Over/Under Frequency; Anti-Islanding; Over Current; Reverse DC Polarity; Overload Protection
|
|||
Protection Degree
|
NEMA-6 / IP-66 / IP-67
|
|||
Ambient Temperature
|
-40°F to +149°F (-40°C to +65°C)
|
|||
Operating Temperature
|
-40°F to +185°F (-40°C to +85°C)
|
|||
Display
|
LED LIGHT
|
|||
Comunications
|
Power Line
|
|||
Dimension (W-H-D)
|
7.09" x7.32" x 0.98" (180x186x25 mm)
|
10.91"x5.20"x1.97"(277x132x50 mm)
|
10.91"x5.20"x1.97"(277x132x50 mm)
|
8.8"x8.2"x1.38" (268x250x42 mm)
|
Weight (including AC cable)
|
3.3 lbs. (1.5 kg)
|
8.8 Ibs. (4.0 kg)
|
6.4 Ibs. (2.9 kg)
|
6.4 Ibs. (2.9 kg)
|
Environment Category
|
Indoor and outdoor
|
|||
Wet Location
|
Suitable
|
|||
Pollution Degree
|
PD3
|
|||
Overvoltage Category
|
II(PV), III (AC MAINS)
|
|||
Product Safety Compliance
|
UL 1741
CSA C22.2
No. 107.1; IEC/EN 62109-1
IEC/EN 62109-2
|
|||
Grid Code Compliance* (Refer to the label for the
detailed grid code compliance) |
IEEE 1547; VDE-AR-N 4105*
VDE V 0126-1-1/A1
G83/2, CEI 021
AS 4777.2 & AS
4777.3,EN50438
|
* Open station supports one-click installation and registration